Cognitive Solutions Cxi Betriebsanweisung Seite 234

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 292
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 233
RFID COMMANDS
222 Copyright © 2006, Cognitive.
!RFID TIMEOUT
Function This command sets the time delay, in milliseconds,
to wait before considering a command a failure.
NOTE: The parameters are part of a calculation and do
not translate into exact execution time differences.
Explicit Form
!RFID TIMEOUT bb,ss,rr,ww,ll
Parameters
bb
Base Time Out – Specifies the time
delay in milliseconds. The range of this
parameter is 0 through 5000.
ss
Base Time Out – Specifies the time
delay in milliseconds. The range of this
parameter is 0 through 5000.
rr
Read Time Out – Specifies the time
delay in milliseconds. The range of this
parameter is 0 through 5000.
ww
Write Time Out – Specifies the time
delay in milliseconds. The range of this
parameter is 0 through 5000.
ll
Lock Time Out – Specifies the time
delay in milliseconds. The range of this
parameter is 0 through 5000.
Command Type RFID Setup/Debug Command
Seitenansicht 233